How do I Calibrate the ECO2 Touch Screen?

Over time you may find that when you press keys on your overlay, you don't see what you are supposed to see; or you may notice that the icons and images on the display screen don't seem to fit the display area as well as they once did.  This is normal with a touch screen and can be easily fixed.

 

To Recalibrate the Display:

Note:  You must be in CORE, the Toolbox, or a Custom Page to recalibrate your screen.  You cannot do this from a menu or when you are using an internal computer application.

 

1.   On the top front of the case, press and hold the TOOLS Tools key key while you activate the #2 USER DEFINED User Define Key 2 key on the case (The key that was pre-programmed as the SET-UP key).

NOTE:  If your system lock is turned on, you must turn it off to Calibrate the Touchscreen.

2.   Release both keys.

3.   You see a message that tells you to TOUCH in the middle of 4 shrinking arrows.  This screen is on a time limit which requires you to touch on this spot within 10 seconds.  If this screen times out you must repeat steps 1 and 2.

4.   With a stylus, the eraser end of a pencil, or a pen cap, press on the dot in the middle of the shrinking arrows.  You will need to press and hold this location for 1 second.  While holding this spot, you will notice the word TOUCH now goes to HOLD then to RELEASE when activated. Repeat this process at all 4 locations.

5.   You will now see a screen asking you to Please Do Not Touch the Screen.  This screen will time out and return you to the Toolbox.

6.  Repeat this process if needed.